Arbor APS Upgrade Procedure
Basically, the upgrade firmware step was very similar with Arbor other product.
Upgrade Procedure
- Use WebUI upload file to system disk.
- Administration → Files → Upload File
- Upload both arbos & Pravail-APS file.(EX: arbos-5.3-ECZG-i686 & Pravail-APS-5.5.1-ECZG)
- Build code must be same with each other. (5.5.1 = ECZG, 5.5.0 = DKHC, 3.1.2 = DIIG, 3.1.0 = DFYD).
- Check files were uploaded from command
admin@arbos:/# system files directory disk Directory listing of device disk: Filename Kbytes Date/Time Type Pravail-APS-5.5.1-ECZG 207548 Jun23 2014 Signed package arbos-5.3-ECZG-i686 106156 Jun23 2014 Signed package pravail_ssh_key.pub 1 May26 19:01 Text file ssh_host.keys 10 May26 19:33 SSH host keys Free space: 1.7G of 2.0G (14% used)
- Check system running file
admin@arbos:/# system files show Installed packages: ArbOS_5.3 ArbOS 5.3 system files (build DKHC) (arch i686) Pravail-APS-5.5 Arbor Networks Pravail APS 5.5 (build DKHC) (arch i686) admin@arbos:/# system files uninstall Pravail-APS-5.5
- Start Upgrade
- Stop APS Service
admin@arbos:/# services aps stop Stopping Pravail APS services...done. admin@arbos:/#
- Uninstall APS (get file name from # system files show)
admin@arbos:/# system files uninstall Pravail-APS-5.5
- Install New ArborOS
admin@arbos:/# system files install disk:arbos-5.3-ECZG-i686 Extracting package...done. Changes to ArbOS will take effect after the next reload.
- Reboot APS
admin@arbos:/# reload You are about to reboot the system. Do you wish to proceed? [n] y 094: Rebooting the system.. ...............
- Install APS (after reboot)
admin@arbos:/# system files install disk:Pravail-APS-5.5.1-ECZG Extracting package...done. Collecting inventory information..done Upgrading system (this may take some time).done.
- Start APS Service
admin@arbos:/# services aps start Starting Pravail APS services...................................done.